Service Panel Connectors (Continued)
TABLE 11-3
Connector Name
USB2
NTC ENET
MODEM
Note – All service panel connectors are female connectors.

To Remove the Service Panel

1. Open the back door of the storage system.
2. Remove the screws from the right side of the service panel and swing the panel
out.
3. Identify the location of each cable on the inside of the service panel through the
placement shown in
the inside of the service panel.
4. Close the service panel. Identify the location of each cable on the outside of the
service panel by the placement shown in
Remove all cables from the outside of the service panel.
5. Note the location of the service panel and remove the remaining screws holding
the left side of the service panel to the back of the storage system.
6. Remove the service panel.
Internal
External
USB
USB
RJ45
RJ45
RJ12
RJ12
,
FIGURE 11-1
TABLE 11-2
Comments
Not used.
Used to connect the NTC to the Storage
Service Processor for use by the Sun
StorEdge Remote Response software.
When several geographically located
Storage Service Processors are
aggregated together, the NTC ENET
port is connected to the Ethernet router
LAN port using a straight-through
cable.
Used to support the Sun StorEdge
Remote Response option. This port
provides an RS-232 serial protocol port
to be connected to the externally
located modem. When the Sun
StorEdge Remote Response option is
not installed, this port is not used.
, and
. Remove all cables from
TABLE 11-3
,
FIGURE 11-1
TABLE 11-2
Chapter 11 Servicing the Service Panel
, and
.
TABLE 11-3
11-5