Sun Microsystems StorEdge 3900 Series Reference And Service Manual page 211

Hide thumbs Also See for StorEdge 3900 Series:
Table of Contents

Advertisement

5. Reconnect all cables that connect the virtualization engine to the switches and the
storage interface.
6. Replace the power cable.
7. Log in to the Storage Service Processor.
8. Identify the MAC address for the new virtualization engine and replace the entry
for the failed virtualization engine's MAC address in the /etc/ethers file on the
Storage Service Processor. See the ethers(4) man page for details. For example:
8:0:20:7d:93:7e virtualization-engine-name
Refer to
virtualization-engine-pairname values.
9. Ensure that the RARP daemon (in.rarpd(1M)) is running on the Storage Service
Processor.
msp0# /bin/ps -eaf | grep rarpd
root
317
314
msp0#
If the daemon is not running, start it with the following command:
msp0# /usr/sbin/in.rarpd dmfe 1
10. Ensure there is no traffic on the virtualization engine pairs or on the switches, and
type:
msp0# /opt/SUNWsecfg/flib/setveport -v virtualization-engine-name -d
11. Power up the virtualization engine.
12. Log in to the new virtualization engine. The name of the virtualization engine
will be either v1a, v1b, v2a, or v2b.
to review the valid virtualization-engine-name and
TABLE 3-2
0
Sep 28 ?
0:00 /usr/sbin/in.rarpd dmfe 1
Chapter 15 Servicing the Virtualization Engines
15-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents