Storage Service Processor Switch Commands - Sun Microsystems StorEdge 3900 Series Reference And Service Manual

Hide thumbs Also See for StorEdge 3900 Series:
Table of Contents

Advertisement

modifyt3config(1M)–Configures Sun StorEdge T3+ arrays to user-specified
options and updates the configuration snapshot file.
modifyt3params(1M)–Modifies the parameters of the Sun StorEdge T3+ arrays.
This command does not alter existing LUN configurations.
restoret3config(1M)–Restores Sun StorEdge T3+ array configurations with
static saved configurations from the snapshot file. This functionality might be
needed in case of loss of LUNs or the replacement of Sun StorEdge T3+ arrays.
The Sun StorEdge T3+ array configuration is restored to the previously saved
configuration.
By default, this utility compares the existing configuration with the saved one. If
they are identical, the saved configuration is not restored. If the configuration is
the same but the LUNs are in an unmounted state, the command will attempt to
mount the LUNs. If no checks with the saved configuration are needed, you must
specify the -f (force) option.
Caution – If a LUN is not mounted, restoret3config performs a mount on that
LUN. However, if any of the RAID configuration information is different, you might
lose data. To avoid this, run the checkt3config command to verify that the RAID
configuration has not changed before using the restoret3config command.
rmt3group(1M)–Removes a WWN group from a Sun StorEdge T3+ array.
rmt3slice(1M)–Deletes a specified slice from a Sun StorEdge T3+ array volume
or all slices on a specified volume. This command is valid only on Sun StorEdge
3900 series that have volume slicing enabled.
savet3config(1M)–Writes the latest information from the Sun StorEdge T3+
array into the snapshot file.
sett3lunperm(1M)–Sets the permissions for a Sun StorEdge T3+ array LUN.
You can set LUN permissions on an individual, LUN WWN, or group basis. This
command is valid only on Sun StorEdge 3900 series that have volume slicing
enabled.
showt3(1M)–Reads and displays information from Sun StorEdge T3+ arrays.
showt3 uses some Sun StorEdge T3+ internal commands to obtain information.
The Sun StorEdge T3+ commands include ver, vol list, vol stat, volslice
list, lun perm list, lun map list, lun wwn list, hwwn list, port
list, port listmap, sys list, and fru stat.
5.3.3

Storage Service Processor Switch Commands

The following utilities are used to manage the Sun StorEdge network FC switch-8
and switch-16 switches that are used in Sun StorEdge 3900 and 6900 series.
Chapter 5 Configuration Utilities
5-51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents