7.4
Setting up LUN Slicing and Masking on
the Sun StorEdge 3900 Series
The batch process for creating logical unit number (LUN) slicing and masking is
accomplished by running the runsecfg(1M) command on the Storage Service
Processor. The runsecfg(1M) command initiates a series of menus that allow you
to set up parameters for LUN slicing and masking. See Chapter 5 for instructions
about logging in to the Storage Service Processor.
7.4.1
Enabling Sun StorEdge T3+ Array Volume Slicing
The following menus are examples of enabling a volume for LUN slicing.
After logging in to the Storage Service Processor, issue the following command:
# /opt/SUNWsecfg/runsecfg
Select "T3+ Configuration Utility" from the main menu and the following menu is
displayed:
Sun StorEdge T3+ Array Main Menu
1) Display Sun StorEdge T3+ Array(s)
2) Save Sun StorEdge T3+ Array Configuration
3) Configure Sun StorEdge T3+ Array(s)
4) Restore Sun StorEdge T3+ Array Configuration
5) Verify Sun StorEdge T3+ Array Configuration
6) Modify Sun StorEdge T3+ Array Sys Parameters
7) Display Sun StorEdge T3+ Array(s) Configuration Status
8) Manage Sun StorEdge T3+ Array LUN Slicing
9) Manage Sun StorEdge T3+ Array LUN Masking
10) Help
11) Return
Select option above:> 8
Chapter 7 Sun StorEdge 3900 and 6900 Series Setup Instructions
7-7