Advertisement

4. Type binary to set the transfer mode.
The data format must be set to binary.
5. Type put filename to download the file to the virtualization engine.
/opt/svengine/firmware/fw8_17.ima is the file name for version 8.17
firmware.
/svengine/sdus/FCFC3SUN.ima is the file name for version 8.014 firmware.
Before the file data is loaded into flash memory, checks are performed to ensure that
the file contains valid microcode in the correct format. When this completes, the
virtualization engine will reboot.
6. Type bye to end the ftp session.

To Replace the HBAs

The following steps assume the failed HBA has an associated worldwide name
(WWN) alias and it is currently in a serial loop intraconnect (SLIC) zone. The new
HBA (new-wwn and new-alias) will replace it.
1. Add the new HBA WWN and alias into the virtualization engine SLIC zone.
Note – You must perform this step first, in case there is only a single HBA in that
zone. A zone cannot exist with no HBAs.
# addtovezone -n v1 -z sliczone -w new-wwn -a new-alias
2. Remove the failed HBA alias with the associated WWN and SLIC zone. For
example:
# delfromvezone -n v1 -z sliczone -a old-alias
15-6
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002