Sun Microsystems StorEdge 3900 Series Reference And Service Manual page 196

Hide thumbs Also See for StorEdge 3900 Series:
Table of Contents

Advertisement

9. Ensure the RARP daemon (
Processor. For example:
msp0# ps -eaf | grep rarpd
root 317 314 0 sept 28 ? 0:00 /usr/sbin/in.rarpd dmfe 1
msp0#
If the daemon is not running, start it with the following command:
msp0# /usr/sbin/in.rarpd dmfe 1
10. Power on the FC switch.
11. Type:
# /opt/SUNWsecfg/bin/restoreswitch -s switch-name
12. Type:
msp0# /opt/SUNWstade/bin/config_solution -m model-number
13. Bring up the Storage Automated Diagnostic Environment and replace the old
switch name with the new one.
Refer to the Storage Automated Diagnostic Environment User's Guide for detailed
instructions on device discovery.
14. Log out of the Storage Service Processor.
15. Replace the grill that covers the FC switch.
The switch initialization and flash update procedures are in the SANbox-8/16
Segmented Loop Switch Management User's Guide.
the base configuration of the Sun StorEdge network FC switch-8 and switch-16
switches. See the procedures in this chapter for the configuration utilities used to
modify the base configuration.
13-4
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002
(1M)) is running on the Storage Service
in.rarpd
TABLE 3-13
through
give
TABLE 3-18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents