15. Cut the small wire tie on the back of the Storage Service Processor and remove the
smart card from the unit.
To Replace the Storage Service Processor
Without the Remote Response Enabled
1. Establish a connection to the Storage Service Processor.
a. Connect one end of the standard cable into the serial console port of the service
panel.
b. Connect the other end of the standard cable to an available serial port on one of
the following devices:
The cables and DB9 and DB25 adapters are shipped with the storage system.
2. From the onsite system, establish a connection to the Storage Service Processor.
The commands used to make the connection varies depending on the onsite system.
For example, from a Solaris server, you would type:
# tip -9600 /dev/ttyb
Connected
When the connection is made, press Return.
3. Log in as root:
Console login: root
Password: password
4. Change all references of the host name to the name returned in Step 3 of the
Section t, "To Remove the Storage Service Processor" on page 12-13 in the
following files:
12-14
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002
Laptop
Workstation
Server
/etc/nodename
/etc/hostname.dmfe0
/etc/net/ticlts/hosts
/etc/net/ticots/hosts
/etc/net/ticotsord/hosts
/etc/inet/hosts