5. Change the Storage Service Processor LAN entry in the /etc/netmasks file so
that it matches your local-IP-address. See the netmasks(4) man page for details.
6. Add the appropriate entries for the Sun StorEdge network FC switch-8 or switch-
16 switch, virtualization engines, and the Sun StorEdge T3+ arrays to the
/etc/ethers file. See the ethers(4) man page for details.
7. Change the root password.
8. Set the /etc/TIMEZONE file to the desired time zone. A typical line from the
/etc/timezone file appears as follows:
US/Eastern
See the timezone(4) man page for details.
9. Reboot the Storage Service Processor.
msp0# /etc/reboot
10. Attach the Storage Service Processor dmfe 1 port to the Ethernet hub on the Sun
StorEdge 3900 or 6900 series LAN.
11. Reconnect all remaining cables.
12. Type:
msp0# /opt/SUNWstade/bin/config_solution -m model-number
13. Bring up the Storage Automated Diagnostic Environment and replace the old
Storage Service Processor name with the new one.
Refer to the Storage Automated Diagnostic Environment User's Guide for detailed
instructions on Storage Service Processor discovery.
14. Type:
msp0# /opt/SUNWsecfg/bin/savet3config -n all
msp0# /opt/SUNWsecfg/bin/savevemap -n [v1,v2]
msp0# /opt/SUNWsecfg/bin/saveswitch -s all
East.Sun.COM
# Sun East Coast
Chapter 12 Servicing the Storage Service Processor
12-15