Sun Microsystems StorEdge 3900 Series Reference And Service Manual page 212

Hide thumbs Also See for StorEdge 3900 Series:
Table of Contents

Advertisement

13. Connect with the replaced virtualization engine using telnet(1). Select Option 9
from the main menu, then enter a Q and a Y. For instance:
> telnet v1a
Trying 192.168.0.20...
Connected to v1a.
Escape character is '^]'.
Connection to the Vicom SAN router has been established.
Enter password:
Password accepted!
User Service Utility Key Assignments:
'?': Show User Service Utility Key Assignments Menu
'1': Show VPD
'2': Show LUN Map
'3': Download SVE Microcode from Local Computer
'4': View/Change Response to SV Management Programs
'5': Clear Error Log
'6': View/Change Interface Configuration
'9': Clear SAN database
'B': Reboot Router
'Q': Quit Serial Port Service Utility
9
...
Q
...
Y
14. Set the virtualization parameters to the default settings. Type:
# /opt/SUNWsecfg/bin/setupve -n virtualization-engine-name
15. Wait 30 seconds and type the following to verify that the settings are correct:
# /opt/SUNWsecfg/bin/checkve -n virtualization-engine-name
15-4
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002