TABLE 14-1
FRU Description
Sun StorEdge T3+ array partner group
(ASSY,T3CES RR 2X9X180G)
Sun StorEdge T3+ mounting tray
Sun StorEdge T3+ array ES rack kit
The only tool required to service a Sun StorEdge T3+ array is:
1/4-inch slotted screwdriver

To Remove a Sun StorEdge T3+ Array

1. Determine which Sun StorEdge T3+ array should be replaced.
2. Turn off the Sun StorEdge T3+ array partner group and disconnect the
interconnect cables.
Refer to the Sun StorEdge T3 and T3+ Array Installation, Operation, and Service Manual
for information on disconnecting the cables.
3. Remove the defective Sun StorEdge T3+ array. If it is the alternate in the partner
group, skip to Step 1.
4. Identify the new MAC address for the replacement Sun StorEdge T3+ array.
The MAC address of the Sun StorEdge T3+ array can be found on a card inside the
front cover of the device.
5. Change the MAC address from the defective Sun StorEdge T3+ array to the
replacement Sun StorEdge T3+ array in the /etc/ethers file on the Storage
Service Processor. See the ethers(4) man page for details. For example:
8:0:20:7d:93:7e Sun-StorEdge-T3+-name
14-2
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002
Sun StorEdge T3+ Array Partner Group FRU list
Part Number
595-6302-01
9676A
4663A