Table 3-17 Sun Storedge 6960 System Configuration; Table 3-18 Sun Storedge 6910 And 6960Sl System Switch Configuration - Sun Microsystems StorEdge 3900 Series Reference And Service Manual

Hide thumbs Also See for StorEdge 3900 Series:
Table of Contents

Advertisement

TABLE 3-17
sw1a
Port 12 = F (host #10a)
Port 13 = F (host #11a)
Port 14 = F (host #12a)
Port 15 = F (host #13a)
Port 16 = F (host #14a)
TABLE 3-18
sw2a
Two Hard Zones
Zone 1
Port 1 = F (v1a device side)
Port 2 = TL (t3b0)
Port 3 = TL (t3b2)
Port 4 = TL (t3be1)
Port 5 = TL (t3be3)
Port 6 = UNUSED
Port 7 = T (sw2b port 7)
Port 8 = T (sw2b port 8)
Zone 2
Port 9 = F (v2a device side)
Port 10 = TL (t3b1)
Port 11 = TL (t3be0)
Port 12 = TL (t3be2)
Port 13 = TL (t3be4)
Port 14 = UNUSED
Port 15 = T (sw2b port 15)
Port 16 = T (sw2b port 16)
3-18
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002
Sun StorEdge 6960 System Configuration
sw1b
Port 12 = F (host #10b)
Port 13 = F (host #11b)
Port 14 = F (host #12b)
Port 15 = F (host #13b)
Port 16 = F (host #14b)
Sun StorEdge 6910 and 6960SL System Switch Configuration
sw2b
Two Hard Zones
Zone 1
Port 1 = F (v1b device side)
Port 2 = TL (t3b0 altmaster)
Port 3= TL (t3b2 altmaster)
Port 4 = TL (t3be1 altmaster)
Port 5 = TL (t3be3 altmaster)
Port 6 = UNUSED
Port 7 = T (sw2a port 7)
Port 8 = T (sw2a port 8)
Zone 2
Port 9 = F (v2b device side)
Port 10 = TL (t3b1 altmaster)
Port 11 = TL (t3be0 altmaster)
Port 12 = TL (t3be2 altmaster)
Port 13 = TL (t3be4 altmaster)
Port 14 = UNUSED
Port 15 = T (sw2a port 15)
Port 16 = T (sw2a port 16)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents