To Make An Ethernet Terminal Connection - Sun Microsystems StorEdge 3900 Series Reference And Service Manual

Hide thumbs Also See for StorEdge 3900 Series:
Table of Contents

Advertisement

To Make an Ethernet Terminal Connection

1. Configure your Ethernet terminal software so the terminal appears as IP address
10.0.0.n, subnet mask 255.0.0.0, no DNS, no gateway.
Note – If the Storage Service Processor LAN has been reconfigured to a domain
other than 10.0.0.n, you must obtain the valid Ethernet address from the
administrator of the new domain.
If a Storage Service Processor LAN hub exists, connect the Ethernet port of the
terminal to the Ethernet hub using a standard CAT5 Ethernet cable. If no hub
exists, connect the Ethernet port of the terminal to the SP LAN port on the service
panel using the Ethernet crossover cable (part number 530-2149-01).
Note – The 530-2149-01 part number is an industry-standard Ethernet crossover
cable. If the cable is not available, you should be able to use any standard Ethernet
crossover cable, which is available at most electronic component outlets.
2. Type:
telnet 10.0.0.n
Note – If the Storage Service Processor LAN has been reconfigured to a domain
other than 10.0.0.n, you must obtain the valid Ethernet address from the
administrator of the new domain.
The following output is displayed:
Trying 10.0.0.x...
Connected to 10.0.0.x.
Escape character is '^]'.
SunOS 5.8
login:
3. Login as cmdadm.
login: cmdadm
Password: sun1
Chapter 12 Servicing the Storage Service Processor
12-5