Sign In
Upload
Manuals
Brands
Sun Microsystems Manuals
Racks & Stands
StorEdge D2
Sun Microsystems StorEdge D2 Manuals
Manuals and User Guides for Sun Microsystems StorEdge D2. We have
3
Sun Microsystems StorEdge D2 manuals available for free PDF download: Installation, Operation And Service Manual, Best Practices Manual, Installation Manual
Sun Microsystems StorEdge D2 Installation, Operation And Service Manual (118 pages)
Brand:
Sun Microsystems
| Category:
Storage
| Size: 1.85 MB
Table of Contents
Table of Contents
3
Preface
11
Sun Storedge D2 Array Overview
17
Description
18
I "Description
18
Mounting Options
19
Parts
20
Software Options
21
Removable Components
21
Components at the Front of the Array
22
Disks
22
Fillers
22
Front Door
23
Power and Subsystem Leds
23
Disk Leds and Labels
24
Disk Leds
24
Disk Labels
25
Components at the Back of the Array
26
Esm
27
Configuration Options Switch Bank
30
Disk Slot Numbers
31
SCSI Connections
31
Power Supplies
32
Fans
33
Leds on the Power Supplies and Fan Canisters
33
Supported Configurations
35
Single-Bus Configuration
36
Split-Bus Configuration
37
Cluster Configuration
38
Setting up and Configuring the Sun Storedge D2 Array
39
M to Do before You Begin
40
M to Mount the Array on a Desktop or Tabletop
43
M to Configure and Cable the Array
44
M to Configure the Array on the Host
46
Monitoring and Troubleshooting the Sun Storedge D2 Array
51
Sunvts Test Software
52
M to Install Sunvts Software
52
Network Storage Agent
53
M to Install Network Storage Agent
53
Task Overview for Monitoring the Health of the Array
54
Troubleshooting
55
M to Troubleshoot the Array When the Subsystem LED Is Amber
56
Task Overview for Using Network Storage Agent to Locate Faulty Disks
57
M to Find the Device Name of a Faulty Disk
58
M to Bring up the Network Storage Agent Maintain Devices
59
M to Find a Disk's Device Name and SCSI ID on an Update D2
60
M to Find a Drive or Enclosure
62
M to Find an Array by a Unit ID Assigned to the ESM(S)
64
Adding and Replacing Frus
65
Hot- and Cold-Pluggable Frus
66
ESD Precautions
67
Removing and Replacing a Disk Drive
68
Device Naming Conventions
68
Overview of Disk Drive Replacement Procedures
68
M to Prepare to Replace a Disk Drive (UNIX)
70
M to Prepare to Replace a Disk Drive (VXVM)
72
M to Remove a Disk Drive
73
M to Install a Disk Drive
74
I to Restore a File System (UNIX)
75
M to Restore a File System (UNIX)
76
M to Re-Create a VXVM Configuration on the New Disk (VXVM)
77
Removing and Replacing a Fan
78
M to Remove and Replace a Fan Canister
78
FIGURE 4-4 Removing and Replacing a Fan Canister
79
Removing and Replacing a Power Supply
80
To Remove and Replace a Power Supply
80
FIGURE 4-5 Removing and Replacing a Power Supply
80
Removing and Replacing an ESM
82
To Remove an ESM
82
FIGURE 4-6 Pulling out the Metal Locking Bars to Release an ESM
83
FIGURE 4-7 Removing the ESM
84
M to Install an ESM
85
Replacing the Chassis
87
M to Remove the Removable Components from the Chassis
88
M to Remove and Re-Attach the Mounting Tray
89
M to Replace the Removable Components in the Chassis
90
M to Reconfigure the Array on the Host
91
System Specifications
93
Air Flow and Other Clearance Requirements
94
FIGURE A-1 Sun Storedge D2 Array Air Flow Clearance Requirements
94
Physical Specifications
95
Electrical Specifications
95
Environmental Specifications
96
Advertisement
Sun Microsystems StorEdge D2 Best Practices Manual (66 pages)
Brand:
Sun Microsystems
| Category:
Storage
| Size: 0.45 MB
Table of Contents
Table of Contents
3
Preface
11
1 Introduction
15
Features
15
Web Sites
16
Firmware Overview
17
Hardware Overview
18
2 Hardware Installation and Configuration
21
New Installation
21
Power Cables
21
SCSI Cables
22
Cluster and Multi-Initiator Configurations
22
Cluster Information
22
Multi-Initiator Information
23
Supported Configurations
23
Qualified Platforms
23
Disk Drive Support Matrix
24
Supported Sun Storedge D2 Configurations
24
3 Sun Storedge D2 ESM Functional Description
29
Host SCSI
29
Host SCSI Termination Power
29
Host SCSI Disable with no Termination Power
29
Host SCSI Reset with Change in Termination Power
30
Array SCSI
30
SAF-TE Interface
30
SAF-TE Subsystem Interface
30
4 Sun Storedge D2 Array ESM Switches
33
Array Configuration Options Switch
33
Array Unit ID Switch
34
5 Maintenance and Service
35
Verifying Hardware Functionality
35
Array Unit
35
SCSI Cables
36
FRU Replacement
36
Host Adapter
36
Interconnect Cables
37
Leds
37
Subsystem Fault LED
37
Drive Slot N LED
38
Fan Fault LED N
38
Power Fault N LED
38
ESM Over-Temp/Code Download LED
39
Power On/Scsi Active LED
39
Host N Term Power LED
39
6 SAF-TE Command Implementation
43
Inquiry Command
43
SAF-TE Read Buffer Commands
45
Read Enclosure Configuration (00H)
45
Number of Fans
46
Power Supplies
46
Device Slots
46
Number of Temperature Sensors
46
Audible Alarm
47
6.2.1.8 Celsius/Fahrenheit
47
Number of Thermostats
47
Read Enclosure Status (01H)
47
Read Device Slot Status (04H)
49
SAF-TE Write Buffer Commands
51
Write Device Slot Status (10H)
51
Perform Slot Operation (12H)
52
Send Global Flags Command (15H)
53
7 Sun Storedge D2 VPD Settings and Factory Defaults
55
D2 Factory Default Downloadable Image
55
Midplane VPD
57
ESM Card VPD
58
Sense Codes
61
Sun Microsystems StorEdge D2 Installation Manual (16 pages)
Array Cabinet
Brand:
Sun Microsystems
| Category:
Racks & Stands
| Size: 0.59 MB
Advertisement
Advertisement
Related Products
Sun Microsystems DC200
Sun Microsystems Sun StorEdge D1000
Sun Microsystems Differential Dual-Channel
Sun Microsystems Ethernet Device Driver none
Sun Microsystems SPARCstorage DLT 4000
Sun Microsystems DLT 7000
Sun Microsystems Dual
Sun Microsystems DGA 5000
Sun Microsystems StorEdge DVD 10X
Sun Microsystems StorEdge 3900 Series
Sun Microsystems Categories
Server
Storage
Desktop
Computer Hardware
Adapter
More Sun Microsystems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL