Pilz PMCprotego D.48 Operating Manual page 72

Servo amplifiers
Table of Contents

Advertisement

Function Description
Pin
4
5
6
7
8
9
10
11
12
Connector X11B
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
Input/
output
Default setting Description
Off
Folge-InPos
PosReg 0
Off
S_fehl
Off
PosReg1
Off
PosReg2
Off
PosReg3
Off
PosReg4
Off
PosReg5
-
24 VDC
-
I/O-GND
The start of each motion task within an automatic se-
quence of motion tasks is signalled by the inversion of
the output signal. When the first motion task is initiated,
the output registers a low signal. The message may be
varied via the parameters.
May only be set via commands
The output registers a low signal when it leaves the
preset drag error window.
Default: Software limit switch 1, output registers a high
signal
Default: Software limit switch 2, output registers a high
signal
May only be set via parameters
May only be set via parameters
May only be set via parameters
Supply voltage for digital outputs
Earth for the digital signals from the control system
72

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmcprotego d.72

Table of Contents