Function Description
Setting the parameters
The brake function must be enabled in the commissioning software (PASmotion) via the
Brake option ("Motor" window).
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
CAUTION!
Inadequate supply voltage to the motor holding brake can result in a haz-
ardous situation, leading to serious injury and death. The control of the mo-
tor holding brake is not safety-related.
Please consider the power loss due to cable lengths and transition resist-
ances!
Measure the voltage at the brake input!
Test the function of the brakes by releasing and applying the brake.