Intermediate Circuit - Pilz PMCprotego D.48 Operating Manual

Servo amplifiers
Table of Contents

Advertisement

Wiring
6.6.5

Intermediate circuit

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
The connections for the intermediate circuit are
}
Not short circuit and earth fault proof
}
Not reverse polarity protected.
Connector X8
X8
-RB
Connector pin assignment
Output/input circuit
Connection
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
+RB
W2 V2
U2
-DC +DC PE
Designation
-RB
+RB
-DC
+DC
Description
Connection of external brake
resistor -
Connection of external brake
resistor +
Intermediate circuit voltage -
DC
Intermediate circuit voltage
+DC
Intermediate circuit
Cable runs ≤ 500 mm:
Use unshielded single wires
(25 mm²)
Cable lengths > 500 mm:
Use shielded cables.