Normal Mode - Pilz PMCprotego D.48 Operating Manual

Servo amplifiers
Table of Contents

Advertisement

Function Description
4.5.1

Normal mode

The behaviour of the servo amplifier always depends on the current setting of various para-
meters (e.g. ACTFAULT, VBUSMIN, VELO, STOPMODE, see commissioning software's
online help).
The diagram below illustrates the correct functional sequence when switching the servo
amplifier on and off.
U
24 V
X4/1
U
BTB/RTO
X3B/14,15
U
L1,L2,L3
X0
U
Intermediate
circuit X8
U
STO-ENABLE
X4/5, 7
STO-Status
X4/6, 8
U
HW-ENABLE
X3A/1
SW-ENABLE
n
Motor
speed
U
Output stage
enable
(internal)
Fig.: Switching on and off under normal conditions
Servo amplifiers on which the "Holding brake" function has been enabled have a separate
procedure to switch off the inverted rectifier (see section in this chapter entitled "Motor hold-
ing brake").
The drive is shut down safely using the safety function STO (STO1-ENABLE/STO2-EN-
ABLE).
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
<15 s (Boot-time)
~ 500 ms
>100 ms
t
t
t
t
5...8 min
t
t
t
VEL0
t
t
81