External Brake Resistor - Pilz PMCprotego D.48 Operating Manual

Servo amplifiers
Table of Contents

Advertisement

Wiring
Use the following fuses, depending on the device type.
Device type
Blow-out fuse or similar
Protection
6.6.4

External brake resistor

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
Connector X8
X8
-RB
Connector pin assignment
Output circuit
PMCprotego
Connection
Use the following fuses for F
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
+RB
W2 V2
U2
-DC +DC PE
X8
+RB
-RB
B1
INFORMATION
The specified fuses do not protect the external brake resistor from thermal
overload. Monitoring is carried out by the servo amplifier via software. It is
assumed that the parameters on the servo amplifier are set correctly. The
fuses should provide protection from consequential damage in the event of
a short circuit and earth fault.
D.48
D.72
8 A
8 A
Designation
+RBe
-RB
F B1
R Be
F B2
and F
, depending on the device type.
B2
Type
Fine wire fuse or cir-
cuit breaker
Description
Connection of external brake res-
istor +
Connection of external brake res-
istor -
External brake resistor
112