Sincos Encoder With Ssi Interface - Pilz PMCprotego D.48 Operating Manual

Servo amplifiers
Table of Contents

Advertisement

Wiring
Input circuit
Connection
6.8.3.6

SinCos encoder with SSI interface

If the cable length is > 50 m, please speak to our Customer Support.
Connector X5
Connector pin assignment
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
CLOCK
CLOCK\
DATA
DATA\
DATA\
GND
Pin
1
1
6
2
9
3
5
4
5
6
7
8
9
n. c.: Not connected
X5
Absolut SSI
CLOCK
4
CLOCK\
6
DATA
7
DATA\
GND
X1
Designation
GND
n. c.
n. c.
CLOCK\
CLOCK
DATA
DATA\
n. c.
n. c.
Absolute encoder with SSI
interface
Voltage supply and thermal
switch in the motor is con-
nected to X1 via the en-
coder cable.
Twisted pair, shielded
Shield connection in the
connector
Description
Ground
--
--
Test pulse output inverted
Test pulse output
Data
Data inverted
--
--