Control Element; Supply Voltage 24 Vdc - Pilz PMCprotego D.48 Operating Manual

Servo amplifiers
Table of Contents

Advertisement

Wiring
6.7

Control element

6.7.1

Supply voltage 24 VDC

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
Connector X4
STO1-STATUS
STO1-ENABLE
STO2-STATUS
STO2-ENABLE
Connector pin assignment
PMCprotego
Connection
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
WARNING!
Electric shock!
Safe electrical isolation must be ensured for the external power supply that
generates the supply voltage. Failure to do so could result in electric shock.
The power supplies must comply with EN 60950-1, 05/2006, EN 61558-2-6,
11/1997.
Pin
Designation
1
+24 V
X4
8
2
+24 V
7
6
3
XGND
5
4
XGND
3
XGND
4
XGND
+24V
2
+24V
1
X4
1
+24 V
2
+24 V
3
XGND
4
XGND
+24 V
Description
Supply voltage + 24 VDC
Supply voltage + 24 VDC
Earth for supply voltage
Earth for supply voltage
Connected internally:
Pin 1 and 2 (24 V)
L1
Pin 3 and 4 (XGND)
L2
L3
24 V connection isolated
PE
from external power supply,
e.g. with isolating trans-
former
Noise suppression filters in-
tegrated within the servo
amplifier