Commissioning
Establish communication between the PC and servo amplifier
1. Activate Connect and Add Discovered Devices.
2. Click on Serial.
3. Select Baud Rate: 38400.
4. Click on Finish.
A search is made for the connected servo amplifier. If a connection could be estab-
lished, the servo amplifier is displayed below the project name in the project directory.
6. Set parameters for the servo amplifier
Set the basic parameter settings
Please note the following prerequisites:
}
The servo amplifier must not be enabled (ENABLE = 0).
}
The mains voltage must be switched off.
1. Double-click on the relevant servo amplifier in the Project Manager.
The window containing the Device Information is opened in the Drive Configurator.
Information is provided on the servo amplifier (type, serial number, firmware, ambient
temperature).
2. Click on Setup to start the setup wizard.
The Basic Configuration Servo Amplifier window is opened.
You will receive a warning. This refers to the safety precautions that you need to take
because the parameters you enter can be applied on the device immediately.
3. Activate Reset All Servo Amplifier Parameters to Default Values Before Setup.
4. Click on Next.
The Basic Setup window is opened.
5. Select Entry 1: Analogue Speed under Operating Mode.
6. Select the applicable Mains Voltage: 230 V, 400 V or 480 V.
7. Click on Next.
The Motor Parameter-Origin window is opened.
Select motor database
1. Select the Motor Database option.
2. Click on Next.
The Motor Database window is opened.
Select motor from motor database
1. Enter the motor's type code.
You'll find the type code on the motor's type plate. Make your entries using buttons (1)
or (2).
Example: PMCtendo SZ.32/1/X/X/K/H/30
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
189