Wiring
6.7.5.3

Resolver

Under "Connection cables", please note the requirements for the:
}
Cable cross sections
}
Insulation material
If the cable length > 100 m, speak to our Customer Support.
Connector X2
Connector pin assignment
Input circuit
Connection
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
Pin
1
1
6
2
9
3
5
4
5
6
7
8
9
Designation
Shield
ϑ
S4
S3
R2
ϑ
S2
S1
R1
Motor
Description
Internal shield
Thermal switch (+)
Sine input
Cosine input
Reference output
Thermal switch (-)
Sine input
Cosine input
Reference output
Resolver
Thermal switch in the motor
is connected via the re-
solver cable at X2
Twisted pair, shielded
Shield connection in the
connector
129