Pilz PMCprotego D.48 Operating Manual page 113

Servo amplifiers
Table of Contents

Advertisement

Wiring
Fuses – Use in CE regions
Mains voltage power
supply
230 V
400 V
480 V
Conductor cross section --
Fuse type
}
With VBUSBAL 0, 1, 2 (230 V – 400 V):
e.g. fuse type class gRL (gS) from Siba, size 22 x 58 AC 690/700 V and DC 440 V,
30 kA
}
With VBUSBAL 2 qnd 3 (400 – 480 V):
e.g. fuse type class aR from Siba, size 14 x 51 mm DC 700 V, 30/50 kA
Fuse holder
2-pin fuse holder (finger-safe design):
}
14 x 51 mm: Siba, Part No: 51 058 04.2
}
22 x 58 mm: Siba, Part No: 51 060 04.2
Fuses – Use in UL-cUL regions
Mains voltage
power supply
230 V
400 V
480 V
Conductor cross sec-
tion
Fuse type
Bussmann:
}
up to 100 A: FWP-zzzA22F, size 22 x 58 mm with 500 Vdc UL approval
Fuse holder
Bussmann:
}
CH142D, CH222B
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
Voltage class of DC
fuse
Min. 250 VDC
Min. 440 VDC
Min. 600 – 1000 VDC
Voltage class of DC
fuse
Device type D.48, D.72
Min. 250 VDC
100 A
Min. 440 VDC
100 A
Min. 600 – 1000
100 A
VDC
--
35 mm
Device type D.48, D.72
100 A
100 A
100 A
2
35 mm
2
113