Expansion Cards; Expansion Card Pmcprotego S1-2, Pmcprotego S2-2; Expansion Card I/O-14/08 - Pilz PMCprotego D.48 Operating Manual

Servo amplifiers
Table of Contents

Advertisement

Function Description
4.4

Expansion cards

4.4.1

Expansion card PMCprotego S1-2, PMCprotego S2-2

The expansion cards PMCprotego S1-2 and PMCprotego S2-2 are available as accessor-
ies (see Type code).
The safety card monitors safety functions in accordance with EN 61800-5-2. It monitors
safe motion sequences on drives, which are safely brought to a stop and shut down in the
event of an error.
The safety card is built into a servo amplifier PMCprotego D. This converts the servo ampli-
fier into a safe servo amplifier.
4.4.2

Expansion card I/O-14/08

The expansion card I/O-14/08 is available as an accessory.
Functions:
}
14 additional digital inputs and 8 digital outputs
}
The function of the inputs and outputs can be configured in the commissioning soft-
ware.
}
The inputs initiate the motion tasks that are stored in the servo amplifier.
}
The outputs signal the status of the integrated position controller to the higher level con-
trol system.
}
The functions of the inputs and outputs correspond to the functions that can be as-
signed to the digital inputs and outputs on connector X3 of the servo amplifier.
}
The inputs and outputs are isolated from the servo amplifier through optocouplers.
Fig.: Front view of expansion card I/O-14/08
LEDs:
LED
Green
Red
Operating Manual PMCprotego D.48, PMCprotego D.72
1001735-EN-04
INFORMATION
Detailed information about the function range can be found in the operating
manuals for the PMCprotego S1-2 and PMCprotego S2-2.
Description
24 V supply voltage is present
Fault on the expansion card's outputs (overload and/or short circuit)