10172
Sweep Time too fast(<2sec)
The sweep time must be set to 2 seconds or longer for
the results to be valid.
10141
Sync word not found in frame (Burst Type)
One or more active GSM bursts that match the selected
Burst Type have been detected in the RF Input signal,
but none contain the selected Training Sequence Code
(TSC). The search was performed over the complete
GSM frame.
10143
Sync word not found in frame (Ref Burst)
One or more active GSM bursts that match the selected
Burst Type have been detected in the RF Input signal,
but none contain the selected Training Sequence Code
(TSC). The search was only performed using the
Reference Burst type and Reference TSC settings over
the complete GSM frame.
10142
Sync word not found in specified timeslot
(Burst Type)
One or more active GSM bursts that match the selected
Burst Type have been detected in the RF Input signal,
but none contain the selected Training Sequence Code
(TSC). The search was only performed over the
specified timeslot setting.
10259
Table could not be loaded.
When trying to load a table, the previous table has been
somehow corrupted. Use the
valid table. Then edit the valid table, save it, and try to
load it again.
10259
Table could not be saved.
This message occurs if C: drive is full or corrupt. Check
the amount of space left on the drive.