Installation troubleshooting
...................................................................................................................................................................................................................................

Procedure A-7: Circuit pack alarm handling

Overview
The procedure described below should be performed if the "Fault" LED is flashing on
one or more circuit packs or if circuit pack alarms are displayed in the WaveStar
alarm list after a system reset.
Required equipment
Prior to performing this task, the following equipment must be available:
1. WaveStar
2. CAT5 crossover LA cable with RJ-45/RJ-45 connectors (see chapter 4,
"CIT connection (LA crossed)" (p.
Prerequisites
Prior to performing this task, you must:
1. be logged in to WaveStar
2. be logged in to the E.
Procedure
Proceed as follows to perform a circuit pack reset:
...................................................................................................................................................................................................
In the WaveStar
1
Result:
...................................................................................................................................................................................................
2
Specify the slot where the corresponding circuit pack resides by selecting the slot from
the equipment selection tree on the left-hand side of the Reset Slot/Circuit Pack
window. Alternatively, you may also enter the slot AID directly into the Enter AID field.
...................................................................................................................................................................................................
Click Select.
3
...................................................................................................................................................................................................
Select Controller as Reset Type on the right-hand side of the Reset Slot/Circuit
4
Pack window.
...................................................................................................................................................................................................
Click Apply and then Yes in the confirmation window.
5
...................................................................................................................................................................................................................................
A-12
®
CIT PC
®
CIT as Super User.
®
CIT System View, select Fault → Reset → Slot/Circuit Pack....
The Reset Slot/Circuit Pack window appears.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure A-7: Circuit pack alarm handling