Procedure A-10: Remote login failure

Overview
The procedure described below should be performed if no remote login is possible (see
chapter 10, section
(p.
10-15)).
Procedure
Proceed as follows in the case of a remote login failure:
...................................................................................................................................................................................................
Check that the DCC channels are configured correctly (see chapter 10, section
1
10-2: "Provision DCC" (p.
IF ...
a remote login is not possible,
a remote login is possible,
...................................................................................................................................................................................................
2
Reset the CTL unit of the near-end E. To do this, open the latches simultaneously and
wait until the red LED is illuminated continously. Then pull and reinsert the controller.
IF ...
a remote login is not possible,
a remote login is possible,
...................................................................................................................................................................................................
Reset the CTL unit of the far-end E.
3
IF ...
a remote login is not possible,
a remote login is possible,
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
Procedure 10-3: "WaveStar
10-12)).
THEN ...
proceed to Step 2.
E D OF STEPS
THEN ...
proceed to Step 3.
E D OF STEPS
THEN ...
proceed to Step 4.
E D OF STEPS