Network establishment and testing
...................................................................................................................................................................................................................................
3. SDH/SO ET analyzer
The required transmission rate depends on the optical circuit packs used within the
ring. The optical circuit pack with the lowest transmission rate determines the
transmission rate which should be used for the test. For example, if OP2G5 and OP10
circuit packs are used, an STM-16/OC-48 transmission signal is required.
4. ESD wrist strap.
Prerequisites
Prior to performing this task, you must have done the following:
1. Set up the S CP/UPSR test (see section
(p.
2. Logged in to WaveStar
"Starting the WaveStar
been enabled during WaveStar
3. Logged in to E-A.
Automatic ring switching
Proceed as follows to test the automatic S CP/UPSR ring switching:
...................................................................................................................................................................................................
Start a signal transmission via the SDH/SO ET analyzer.
1
Result:
...................................................................................................................................................................................................
2
In the WaveStar
...................................................................................................................................................................................................
Select the existing Path Protection in the Ptn Grp tab on the left-hand side of the
3
window and click the Select button.
...................................................................................................................................................................................................
Check that "Working" is indicated as the Active path. Do not close the window.
4
...................................................................................................................................................................................................
Remove the fiber connection between E-A and E-B.
5
Result:
of about 15 ms is caused.
...................................................................................................................................................................................................
Click Refresh.
6
...................................................................................................................................................................................................................................
10-72
10-43)).
®
CIT as Super User (see chapter 5, section
®
CIT application" (p.
o bit errors are present.
®
CIT System View, select View → Protection....
An immediate switch to the "Protection" path and a short traffic interruption
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 10-8: "S CP/UPSR test setup"
5-18)) if WaveStar
®
CIT installation.
Test procedures
Procedure 10-13: SNCP/UPSR test
Procedure 5-4:
®
CIT User Login has
365-374-198R10.5.4