Network establishment and testing
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Check that the RING Node APS (Automatic Protection Switch) State field displays
7
"Switching".
...................................................................................................................................................................................................
Click Close.
8
...................................................................................................................................................................................................
Repeat
9
To do that, enter the following:
• The E TID as NE Name
• 1675 LambdaUnite MSS as NE Type
• OSI as Connection Type.
ote the following for
E-B: "Switching" will be displayed in the RING Node APS (Automatic
Protection Switch) State field.
E-C and E-D: "Passthrough" will be displayed in the RING Node APS
(Automatic Protection Switch) State field.
...................................................................................................................................................................................................
Re-install the fiber connection between E-A and E-B.
10
Result:
is caused (a short traffic interruption of about 15 ms can be observed).
...................................................................................................................................................................................................
Check in each E that the RING Node APS (Automatic Protection Switch) State
11
field displays "Idle".
...................................................................................................................................................................................................
Close the View Protection window in each E by clicking Close.
12
E
N D
O F
...................................................................................................................................................................................................
Manual ring switching
Proceed as follows to test the manual MS-SPRing/BLSR ring switching:
...................................................................................................................................................................................................
In the WaveStar
1
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
Step 4
to
Step 8
for all other Es within the ring via remote login.
Step
7:
After the defined WTR time (5 minutes) a switch back to the "Working" path
S T E P S
®
CIT System View of E-A, select Fault → Protection Switch....
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 10-11: 2-fiber MS-SPRing/BLSR test