NE provisioning
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................
16
IF ...
TCP/IP access is required,
TCP/IP access is not required,
...................................................................................................................................................................................................
In the WaveStar
17
Condition... → Exit Maintenance Condition....
Result:
about ten minutes). As a consequence, the management association between the
WaveStar
After the boot process the following must be observed:
• The "Active" LEDs on all circuit packs are permanently illuminated with the
• Only the "AB " LED on the User Panel is illuminated.
Troubleshooting: If the "Fault" LED is flashing on one or more circuit packs or if
circuit pack alarms are displayed in the WaveStar
A, section
...................................................................................................................................................................................................
18
Proceed with section
E
N D
O F
S T E P S
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................................................
7-20
®
CIT System View, select Fault → Enter/Exit Maintenance
The 1675 LambdaUnite MSS E will now perform a system reset (takes
®
CIT and the E will be lost.
exception of the XC protection pack in slot "XC P" (#10). o LED is illuminated
on this circuit pack.
This is because the system timing is not yet provisioned (see section
7-10: "System timing" (p.
Procedure A-7: "Circuit pack alarm handling" (p.
Procedure 7-6: " E password aging" (p.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
THEN ...
skip the following steps and proceed with section
Procedure 7-5: "LA port configuration for TCP/IP
access" (p.
7-23).
proceed with
Step
17.
7-38)).
®
CIT alarm list, refer to appendix
Provisioning system parameters
Procedure 7-4: System parameters
Procedure
A-12).
7-29).
365-374-198R10.5.4
Issue 1 July 2009