Purpose
This section provides a procedure for launching the WaveStar
for the first time.
Required equipment
Prior to performing this task, the following equipment must be available:
1. WaveStar
2. CAT5 crossover LA cable with RJ-45/RJ-45 connectors (see chapter 4,
"CIT connection (LA crossed)" (p.
Procedure
Proceed as follows to launch the WaveStar
...................................................................................................................................................................................................
1
Log in to the WaveStar
"Starting the WaveStar
Result:
will take a few minutes and is displayed in the Network View of the WaveStar
...................................................................................................................................................................................................
In the WaveStar
2
...................................................................................................................................................................................................
3
In the WaveStar
Result:
cannot be found in the configuation file. After confirming these messages an Edit
Configuration screen appears.
...................................................................................................................................................................................................
In the Edit Configuration screen you have to modify the entries for all the displayed
4
entries representing O
• Leave the SIG-IP fields unchanged.
• In all UI-IP fields enter the IP address of the WaveStar
...................................................................................................................................................................................................
If necessary edit the Alias field.
5
...................................................................................................................................................................................................................................
10-88
®
CIT PC
®
CIT as Super User (see chapter 5, section
®
CIT application" (p.
®
The WaveStar
CIT will update information from the connected Es. This
®
CIT NE Management View, select View → ONNS View.
®
CIT NE Management View, select File → Discover Network.
A couple of windows appear successively indicating that the IP addresses
S nodes:
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 10-17: Launching the WaveStar
®
CIT ONNS
®
4-72))
®
CIT O
S application for the first time:
5-18)).
®
CIT or "127.0.0.1" (OSI).
ONNS provisioning
®
CIT ONNS
application for the first time
CIT O
S application