Stand-alone test procedures
...................................................................................................................................................................................................................................
Result:
...................................................................................................................................................................................................
Select NORM as Output Mode in the Source to Destination and Destination to
11
Source group boxes.
...................................................................................................................................................................................................
Type a 9-digit number for the cross-connection in the XC Number field or use the
12
automatically generated one.
...................................................................................................................................................................................................
Click the Apply button to apply your settings and confirm the resulting message by
13
clicking Yes.
...................................................................................................................................................................................................
Click Close.
14
...................................................................................................................................................................................................
Verify that the cross-connection is established. Proceed as follows:
15
1. In the WaveStar
2. Select Shelf 1 (DUR) of the Ptn Grp tab
3. Click Select and confirm the resulting message by clicking Yes.
...................................................................................................................................................................................................
Click Close.
16
...................................................................................................................................................................................................
Start a signal transmission via the transmission analyzer for one minute. Use 44.736
17
Mbit/s as signal rate.
OTE: The default DS3 signal format is "C-bit parity". If you want to change this, please
refer to chapter 4 of the "1675 LambdaUnite MSS User Operations Guide".
Result:
...................................................................................................................................................................................................
18
Create a signal error and verify the result with the transmission analyzer.
...................................................................................................................................................................................................
19
IF ...
further DS3 ports must be tested or a
DS3 protection test shall not be
performed,
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
The current data of the cross-connection are displayed.
®
CIT System View, select View → Cross Connection List...
o bit errors are present during this time.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 8-6: DS3 transmission and protection test
THEN ...
proceed to
Step
20.
8-27