Network establishment and testing
...................................................................................................................................................................................................................................
Result:
about 10 ms is caused.
...................................................................................................................................................................................................
Select the Switch Status tab and click Refresh.
7
Result:
...................................................................................................................................................................................................
Re-install the fiber connection between E-A and E-B ("Working" line).
8
Result:
and a short traffic interruption of about 15 ms is caused.
...................................................................................................................................................................................................
Click Refresh.
9
Result:
...................................................................................................................................................................................................
Click Close.
10
E
N D
O F
S T E P S
....................................................................................................................................................................................................................................
Manual line switching
Proceed as follows to test the manual 1+1 MSP/APS line switching:
...................................................................................................................................................................................................
In the WaveStar
1
Result:
...................................................................................................................................................................................................
Select the existing 1+1 MSP# (SDH) or 1+1 APS# (SO ET) in the Ptn Grp tab on the
2
left-hand side of the window and click the Select button.
...................................................................................................................................................................................................
From the Switch Type list, select Manual To Protection.
3
...................................................................................................................................................................................................
Click Apply and then Yes in the confirmation window.
4
Result:
interruption of about 10 ms can be observed).
...................................................................................................................................................................................................
Click Refresh.
5
...................................................................................................................................................................................................................................
10-56
An immediate switch to the "Protection" line and a short traffic interruption of
"Protection (AID#)" will be indicated as the Active Port.
After the defined WTR time (1 minute) a switch back to the "Working" line
"Working (AID#)" will be indicated as the Active Port.
®
CIT System View, select Fault → Protection Switch....
The Switch Protection window appears.
An immediate switch to the "Protection" line is caused (a short traffic
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Test procedures
Procedure 10-10: 1+1 MSP/APS test
365-374-198R10.5.4
Issue 1 July 2009