Alcatel-Lucent 1675 LambdaUnite Installation And System Turn-Up Manual page 377

Multiservice switch, release 10.5.4
Hide thumbs Also See for 1675 LambdaUnite:
Table of Contents

Advertisement

NE provisioning
...................................................................................................................................................................................................................................
Procedure 7-9: External timing references
Overview
This section provides a procedure for configuring the external timing references.
Required equipment
Prior to performing this task, the following equipment must be available:
1. WaveStar
2. CAT5 crossover LA cable with RJ-45/RJ-45 connectors (see chapter 4,
"CIT connection (LA crossed)" (p.
Prerequisites
Prior to performing this task, you must have done the following:
1. Logged in to WaveStar
"Starting the WaveStar
been enabled during WaveStar
2. Logged in to the E.
3. Checked that the correct system mode is selected (SONET mode or SDH mode, see
section
Procedure
Complete the following steps to configure the external timing references:
...................................................................................................................................................................................................
1
In the WaveStar
Timing/Synchronization.
Result:
Timing References tab.
The configuration parameters of the timing references are presented in the form of a
table, whereby each table row corresponds to a particular timing reference.
...................................................................................................................................................................................................
Repeat the following steps for both external timing references (Ext. Ref. 1 and Ext.
2
Ref. 2).
...................................................................................................................................................................................................
In the Port AID column, use the associated list in order to enable or disable an external
3
timing reference.
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
®
CIT PC
®
CIT as Super User (see chapter 5, section
®
CIT application" (p.
Procedure 7-4: "System parameters" (p.
®
CIT System View, select Configuration →
The Configure Timing/Synchronization window appears with the active
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 7-9: External timing references
4-72))
5-18)) if WaveStar
®
CIT installation.
7-16)).
Provisioning system parameters
Figure 4-48,
Procedure 5-4:
®
CIT User Login has
7-35