Stand-alone test procedures
...................................................................................................................................................................................................................................
Required equipment
Prior to performing this task, the following equipment must be available:
1. WaveStar
2. CAT5 crossover LA cable with RJ-45/RJ-45 connectors (see chapter 4,
"CIT connection (LA crossed)" (p.
3. Optical power meter
– Range: –35 ... +20 dBm
– Wavelength: 1310 nm/1550 nm
4. SDH/SO ET analyzer
The required transmission rate depends on the ports to be tested. The optical circuit
pack with the highest transmission rate determines the required transmission rate of
the analyzer. For example, if OP2G5 and OP10 circuit packs are used,
STM-16/OC-48 or STM-64/OC-192 transmission signals are required.
5. Adjustable optical attenuator
6. ESD wrist strap.
Prerequisites
Prior to performing this task, you must have done the following:
1. Logged in to WaveStar
"Starting the WaveStar
been enabled during WaveStar
2. Logged in to the E.
3. Checked that all used optical ports are clean. A cleaning procedure is given in
appendix A, section
Test setup
The following figure illustrates a possible test setup. The number and type of optical
interfaces used depends on the customer configuration.
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
®
CIT PC
®
CIT as Super User (see chapter 5, section
®
CIT application" (p.
®
Procedure A-13: "Fiber cleaning" (p.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 8-5: Receiver sensitivity test
4-72))
5-18)) if WaveStar
CIT installation.
Figure 4-48,
Procedure 5-4:
®
CIT User Login has
A-24).