Alcatel-Lucent 1675 LambdaUnite Installation And System Turn-Up Manual page 486

Multiservice switch, release 10.5.4
Hide thumbs Also See for 1675 LambdaUnite:
Table of Contents

Advertisement

Network establishment and testing
...................................................................................................................................................................................................................................
To do that, enter the following:
• The TID of E-B as NE Name
• 1675 LambdaUnite MSS as NE Type
• OSI as Connection Type.
OTE:
• Select the port that is connected to E-C as port A (Path 1).
• Select the port to which the fiber loop is connected as Port B (Add/Drop).
• Select the port that is connected to E-A as port C (Path 2).
• The port that is connected to E-A must be defined as working path!
...................................................................................................................................................................................................
19
Start a remote login to E-C.
...................................................................................................................................................................................................
In the WaveStar
20
Create to set up a cross-connection.
Result:
...................................................................................................................................................................................................
Select/Activate the Signal Auto Rate Set check box and define the cross-connection
21
rate in the Rate list according to the analyzer signal used. The following values are
possible:
• VC3 (SDH) / STS1 (SO ET)
• VC4 (SDH) / STS3 (SO ET)
• VC44C (SDH) / STS12 (SO ET)
• VC416C (SDH) / STS48 (SO ET)
• VC464C (SDH) / STS192 (SO ET)
Please note that it is not possible to proceed to the next window before selecting the
cross-connection rate.
...................................................................................................................................................................................................
In the XC Application group box, select 2-Way Point-to-Point.
22
...................................................................................................................................................................................................
Click the left Select button to select the source tributary.
23
Result:
...................................................................................................................................................................................................
Select the port that is connected to E-B.
24
...................................................................................................................................................................................................................................
10-48
®
CIT System View, select Configuration → Cross-Connection →
The Create New Cross Connection window appears.
The Ptn Grp selection tab appears.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Network establishment
Procedure 10-8: SNCP/UPSR test setup
365-374-198R10.5.4
Issue 1 July 2009