Installation troubleshooting
...................................................................................................................................................................................................................................
Result:
...................................................................................................................................................................................................
After about two minutes the "Active" LED must be illuminated. Click the Alarm List
6
button and check that there are no alarms related to the reset circuit pack.
IF ...
the requirements described above are
not fulfilled,
the requirements described above are
fulfilled,
...................................................................................................................................................................................................
Replace the circuit pack.
7
E
N D
O F
...................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
A circuit pack reset is performed.
S T E P S
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure A-7: Circuit pack alarm handling
THEN ...
proceed to Step 7.
E D OF STEPS