Network establishment and testing
...................................................................................................................................................................................................................................
Result:
DCC termination provisioning message appears indicating that the LAPD role has
been set on the user side.
...................................................................................................................................................................................................
Click OK, then click Close.
12
...................................................................................................................................................................................................
13
Repeat
To do that, enter the following:
• The E TID as NE Name
• 1675 LambdaUnite MSS as NE Type
• OSI as Connection Type.
To verify that the MS-SPRing/BLSR setup is correct perform the steps mentioned below.
...................................................................................................................................................................................................
14
In the WaveStar
...................................................................................................................................................................................................
Select the existing 2F MS-SPRing# (SDH) or 2F BLSR# (SO ET) on the left-hand side
15
of the window and click the Select button.
Result:
...................................................................................................................................................................................................
Click Close.
16
...................................................................................................................................................................................................
In the WaveStar
17
...................................................................................................................................................................................................
Select the existing 2F MS-SPRing# (SDH) or 2F BLSR# (SO ET) in the Ptn Grp tab on
18
the left-hand side of the window and click the Select button.
...................................................................................................................................................................................................
Select the Protection Group tab.
19
...................................................................................................................................................................................................
Check that the RING Node APS (Automatic Protection Switch) State field displays
20
"Idle".
...................................................................................................................................................................................................
Click Close.
21
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
If the creation of the MS-SPRing/BLSR protection group was successful, a
Step 1
to
Step 12
for all other Es in the ring via remote login.
®
CIT System View, select View → Rings → Ring Map....
All Es of the ring should be displayed on the right side of the window.
®
CIT System View of E-A, select View → Protection....
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 10-6: 2-fiber MS-SPRing/BLSR test setup
Network establishment
10-33