Alcatel-Lucent 1675 LambdaUnite Installation And System Turn-Up Manual page 422

Multiservice switch, release 10.5.4
Hide thumbs Also See for 1675 LambdaUnite:
Table of Contents

Advertisement

Stand-alone test procedures
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Before starting a signal transmission check that the optical output power of the
14
SDH/SO ET analyzer is not too high. The allowed power input ranges for all optical
circuit packs are given in
(p.
10-8).
...................................................................................................................................................................................................
Start a signal transmission via the SDH/SO ET analyzer for three minutes.
15
Result:
...................................................................................................................................................................................................
16
In the WaveStar
Delete to delete the established cross-connection.
Result:
...................................................................................................................................................................................................
Click the Equip tab on the left.
17
...................................................................................................................................................................................................
18
Expand the tree of a circuit pack which contains cross-connections and select the
respective port.
Result:
cross-connections belonging to the respective port are displayed.
...................................................................................................................................................................................................
Select the cross-connection which shall be deleted and click Next>.
19
Result:
...................................................................................................................................................................................................
Select ALL Legs of this cross-connection and click Next>.
20
Result:
cross-connection.
...................................................................................................................................................................................................
Click Finish to delete the cross-connection and confirm the resulting message by clicking
21
Yes.
...................................................................................................................................................................................................
22
Repeat
...................................................................................................................................................................................................................................
8-36
Table 10-1, "Power input ranges of the optical circuit packs"
o bit errors are present during this time.
®
CIT System View, select Configuration → Cross-Connection →
Screen 1 appears.
In the list box on the right the AIDs of all sources and destinations of
Screen 2 appears.
Screen 3 appears. This window contains the parameters of the selected
Step 16
to
Step 21
for all the other cross-connections that have been established.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 8-7: Optical port transmission test (daisy chain
test)
365-374-198R10.5.4
Issue 1 July 2009