Stand-alone test procedures
...................................................................................................................................................................................................................................
• VC416C (SDH) / STS48 (SO ET)
• VC464C (SDH) / STS192 (SO ET)
Please note that it is not possible to proceed to the next window before selecting the
cross-connection rate.
...................................................................................................................................................................................................
In the XC Application group box, select 2-Way Point-to-Point.
5
...................................................................................................................................................................................................
Click the left Select button to select the source tributary.
6
Result:
...................................................................................................................................................................................................
Select the port to which the SDH/SO ET analyzer is connected.
7
Result:
the respective port are displayed.
...................................................................................................................................................................................................
Select the VC/STS which shall be used as the source and click the Select button.
8
...................................................................................................................................................................................................
Select the port to be tested as destination port and the corresponding VC/STS in the
9
Tributary list box.
...................................................................................................................................................................................................
Click the Select button.
10
Result:
...................................................................................................................................................................................................
Select NORM as Output Mode in the Source to Destination and Destination to
11
Source group boxes.
...................................................................................................................................................................................................
Type a 9-digit number for the cross-connection in the XC Number field or use the
12
automatically generated one.
...................................................................................................................................................................................................
Click the Apply button to apply your settings and confirm the resulting message by
13
clicking Yes.
...................................................................................................................................................................................................
Click Close.
14
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
The Ptn Grp selection tab appears.
In the Tributary list box on the right, the AIDs of all VCs/STSs belonging to
The current data of the cross-connection are displayed.
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 8-5: Receiver sensitivity test
8-19