Power, software, and circuit pack installation
...................................................................................................................................................................................................................................
Higher-order switching unit
XC160
1
XC320
Option 1
Option 2
2
Option 3
1
XC640
Option 1
3
Option 2
4
Option 3
5
Option 4
Notes:
1.
Option 1 is the preferred option.
2.
XC320, option 3, is the preferred option for a seamless upgrade from XC160 to XC320.
3.
XC640, option 2, is the preferred option for a seamless upgrade from XC320 to XC640.
4.
XC640, option 3, is the preferred option for maximized automatic I/O slot usage by Telcordia
Technologies.
5.
XC640, option 4, is the preferred option for a seamless upgrade from XC160 to XC640.
Supported slot combinations for LOXC40G2S/1
Lower-order cross-connection units of type LOXC40G2S/1 (2 slots wide, with a
switching capacity of 40 Gbit/s) can be used in the universal slot pairs 3/4, 16/17, 18/19,
36/37, and 38/39. The slot pairs 3/4, 16/17 and 36/37 are worker slots. The slot pairs
18/19 and 38/39 are protection slots. If the worker LOXC40G2S/1 is installed in the slot
pairs 3/4 or 16/17, then the protection LOXC40G2S/1 must be installed in the slot pair
18/19. If the worker LOXC40G2S/1 is installed in the slot pair 36/37, then the protection
LOXC40G2S/1 must be installed in the slot pair 38/39.
The supported slot combinations for the usage of LOXC40G2S/1 units are shown in the
following table. There, "W" represents the working unit, "P" the protecting unit.
...................................................................................................................................................................................................................................
5-52
Slot assignment
LOXC/1 (W)
LOXC/1 (P)
37
39
4
19
17
19
37
39
4
19
17
19
18
19
37
39
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Software and circuit pack installation
Remarks and additional equipage guidelines
The slots 36 and 38 must remain empty.
The slots 3 and 18 must remain empty.
The slots 2 and 17 are reserved, i.e. may be used in case a future
in-service upgrade is planned towards LOXC units which occupy
2 or 3 slots, respectively.
Alternative equipage if slot 4 is occupied.
The slots 16 and 18 must remain empty.
The slots 36 and 38 must remain empty.
The slots 3 and 18 are reserved, i.e. may be used in case a future
in-service upgrade is planned towards LOXC units which occupy
2 slots.
The slots 16 and 18 are reserved, i.e. may be used in case a future
in-service upgrade is planned towards LOXC units which occupy
2 slots.
The slots 36 and 38 are reserved, i.e. may be used in case a future
in-service upgrade is planned towards LOXC units which occupy
2 slots.
Configuration rules
®
365-374-198R10.5.4
Issue 1 July 2009