System cabling and final assembly
...................................................................................................................................................................................................................................
Legend:
1
2
*
Strain relief
If a strain relief is used (pre-mounted only in EBS-2000 racks) the power input cables
must be secured as follows:
...................................................................................................................................................................................................
1
Loosen the used swivel heads (item 1), but do not take them off.
Important! All swivels are preinstalled to 8-9 m [70.8-79.6 lbs-in], for the
strain-relief plate.
...................................................................................................................................................................................................
Run the cables through the swivel heads and the nuts.
2
...................................................................................................................................................................................................
3
Connect the cables to their configuration position on the PDP.
...................................................................................................................................................................................................
Tighten the swivel heads by hand to secure the cables in position.
4
E
N D
O F
...................................................................................................................................................................................................
...................................................................................................................................................................................................................................
365-374-198R10.5.4
Issue 1 July 2009
+DC (red, return)
-DC (blue)
The U-bracket (connection between return and ground) has to be
removed if the return wire is only grounded at the external battery
(BDFB) source (e.g. valid for the USA domestic market); see also
section
S T E P S
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Procedure 4-2: "Ground wiring" (p.
Power and ground cable installation
Power wiring (External battery - PDP)
4-20)).