To set the port and data type, press ENTER. The cursor will blink on the port
field, indicating that this field is active. Use the UP/DOWN control keys to
scroll to the desired port. Press ENTER, and the cursor shifts to the data type
field. Use the UP/DOWN control keys to scroll to the desired data type, and
press ENTER to select it. Possible data types are:
DBEN: Proprietary compact binary format
RTCM: RTCM type 18/19 and 3/22 are enabled
CMR: Compact Measurement Record (CMR) format
OFF: No RTK base station data is output.
Recording Interval (REC INI: ***.*s)
Displays and sets the data recording interval. To change this parameter press
the ENTER key and use the control keys to enter the desired value in
seconds. The default is 20 seconds. The valid range is 0.2 - 999 seconds.
Elevation Mask (ELEV MASK: **)
Displays and sets the RTK data elevation mask. To change this parameter
press the ENTER key and use the control keys to enter the desired value in
degrees. The default is 10 degrees.
Mode (MODE: RTK BASE)
Displays and sets the selected survey mode. Change the survey type by
pressing the ENTER key and use the UP/DOWN control keys to choose the
desired survey mode. Press ENTER to select it. The mode selected will
determine the parameters displayed.
SURVCONF:RTK ROVER
The Survey Configuration menu tree for the RTK rover is shown in Figure 4.4.
The Survey Configuration RTK Rover submenu provides access to the more general
RTK parameters such as data port, data type and the RTK positioning algorithm.
Parameters selected in this menu will affect what parameters are available in the
SURVEY: RTK Rover menu.