NTERFACE
To show information for the MIPs discovered by the CFM protocol:
Click Administration, CFM.
1.
Select Show Information from the Step list.
2.
Select Show Local MIP from the Action list.
3.
Figure 318: Showing Information on Local MIPs
Use the Administration > CFM > Show Information (Show Remote MEP)
page to show MEPs located on other devices which have been discovered
through continuity check messages, or statically configured in the MEP
database and verified through cross-check messages.
CLI R
EFERENCES
"show ethernet cfm maintenance-points remote detail" on page 1579
"clear ethernet cfm maintenance-points remote" on page 1584
P
ARAMETERS
These parameters are displayed:
MEP ID – Maintenance end point identifier.
MA Name – Maintenance association name.
Level – Authorized maintenance level for this domain.
Primary VLAN – Service VLAN ID.
MEP Up – Indicates whether or not this MEP is functioning normally.
Remote MAC Address – MAC address of the remote maintenance
point. (If a CCM for the specified remote MEP has never been received
or the remote MEP record times out, the address will be set to the initial
value of all Fs.)