Parameter Descriptions
31-02 Bypass Trip Time Delay
Range:
0 s
*
31-03 Test Mode Activation
3
3
Option:
[0]
*
[1]
31-10 Bypass Status Word
Range:
0
[0 - 65535 ]
*
31-11 Bypass Running Hours
Range:
0 h
[0 - 2147483647 h]
*
31-19 Remote Bypass Activation
Option:
[0]
*
[1]

3.24 Parameters: 32-** MCO Basic Settings

Parameters in this group are available when VLT
Control Option MCO 305 is installed in the frequency
converter. For information about the option, see the VLT
Motion Control Option MCO 305 Operating Instructions.
32-00 Incremental Signal Type
Option:
[0]
None
[1]
RS422 (5V TTL)
*
[2]
Sinusoidal 1Vpp
[3]
CAN encoder
32-01 Incremental Resolution
Range:
1024
[1 - 1073741823 ]
*

32-02 Absolute Protocol

Option:
[0]
None
*
[1]
HIPERFACE
[2]
EnDat
[4]
SSI
[5]
SSI with filter
[6]
BiSS-C
[7]
BiSS-B
32-03 Absolute Resolution
Range:
8192
[0 - 1073741823 ]
*

32-04 Absolute Encoder Baudrate X55

Option:
[0]
236
Function:
[0 - 300 s]
Function:
Disabled
Enabled
Function:
Function:
Disabled
Enabled
Function:
Function:
Function:
600
Danfoss A/S © 10/2018 All rights reserved.
®
VLT
AutomationDrive FC 301/302
32-04 Absolute Encoder Baudrate X55
Option:
[1]
[2]
[3]
[4]
*
[5]
[6]
32-05 Absolute Encoder Data Length
Range:
25
*
32-06 Absolute Encoder Clock Frequency
Function:
Range:
262 kHz
32-07 Absolute Encoder Clock Generation
Option:
[0]
[1]
*
32-08 Absolute Encoder Cable Length
Range:
®
Motion
0 m
*
®
32-09 Encoder Monitoring
Option:
[0]
*
[1]
[2]
[3]
[4]
32-10 Rotational Direction
Option:
Function:
[1]
*
[2]
[3]
[4]
32-11 User Unit Denominator
Range:
1
*
32-12 User Unit Numerator
Range:
1
*
32-13 Enc.2 Control
Option:
Function:
[0]
No soft changing
*
[1]
Encoder soft changing enable
[2]
Soft zero setting enable
[3]
Encoder soft changing and soft zero enable
1200
2400
4800
9600
19200
38400
[8 - 37 ]
[78.125 - 2000 kHz]
*
Function:
Off
On
[0 - 300 m]
Off
3 Channels
2 Channels
Warning
Alarm
No action
Reference reversed
User units reversed
Uu and Ref reversed
[1 - 1073741823 ]
[1 - 1073741823 ]
Function:
Function:
Function:
Function:
Function:
Function:
Function:
Function: