Parameter Lists
35-0* Temp. Input Mode
35-00 Term. X48/4 Temperature Unit
35-01 Term. X48/4 Input Type
35-02 Term. X48/7 Temperature Unit
35-03 Term. X48/7 Input Type
35-04 Term. X48/10 Temperature Unit
35-05 Term. X48/10 Input Type
35-06 Temperature Sensor Alarm Function
35-1* Temp. Input X48/4
35-14 Term. X48/4 Filter Time Constant
35-15 Term. X48/4 Temp. Monitor
35-16 Term. X48/4 Low Temp. Limit
35-17 Term. X48/4 High Temp. Limit
35-2* Temp. Input X48/7
35-24 Term. X48/7 Filter Time Constant
35-25 Term. X48/7 Temp. Monitor
35-26 Term. X48/7 Low Temp. Limit
35-27 Term. X48/7 High Temp. Limit
35-3* Temp. Input X48/10
35-34 Term. X48/10 Filter Time Constant
35-35 Term. X48/10 Temp. Monitor
35-36 Term. X48/10 Low Temp. Limit
35-37 Term. X48/10 High Temp. Limit
35-4* Analog Input X48/2
35-42 Term. X48/2 Low Current
35-43 Term. X48/2 High Current
35-44 Term. X48/2 Low Ref./Feedb. Value
35-45 Term. X48/2 High Ref./Feedb. Value
35-46 Term. X48/2 Filter Time Constant
5.2.27 36-** Programmable I/O Option
Par.
Parameter description
No. #
36-0* I/O Mode
36-03 Terminal X49/7 Mode
36-04 Terminal X49/9 Mode
36-05 Terminal X49/11 Mode
36-4* Output X49/7
36-40 Terminal X49/7 Analogue Output
36-42 Terminal X49/7 Min. Scale
36-43 Terminal X49/7 Max. Scale
36-44 Terminal X49/7 Bus Control
36-45 Terminal X49/7 Timeout Preset
36-5* Output X49/9
36-50 Terminal X49/9 Analogue Output
36-52 Terminal X49/9 Min. Scale
36-53 Terminal X49/9 Max. Scale
36-54 Terminal X49/9 Bus Control
36-55 Terminal X49/9 Timeout Preset
36-6* Output X49/11
36-60 Terminal X49/11 Analogue Output
36-62 Terminal X49/11 Min. Scale
MG33MP02
Programming Guide
[60] °C
All set-ups
[0] Not Connected
All set-ups
[60] °C
All set-ups
[0] Not Connected
All set-ups
[60] °C
All set-ups
[0] Not Connected
All set-ups
[5] Stop and trip
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
[0] Disabled
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
4 mA
All set-ups
20 mA
All set-ups
0 ReferenceFeedbackUnit
All set-ups
100 ReferenceFeed-
backUnit
All set-ups
0.001 s
All set-ups
Default value
4-set-up
[0] Voltage 0-10V
All set-ups
[0] Voltage 0-10V
All set-ups
[0] Voltage 0-10V
All set-ups
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] No operation
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] No operation
All set-ups
0 %
All set-ups
Danfoss A/S © 10/2018 All rights reserved.
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-3
TRUE
-
TRUE
0
TRUE
0
TRUE
-3
TRUE
-
TRUE
0
TRUE
0
TRUE
-3
TRUE
-
TRUE
0
TRUE
0
TRUE
-5
TRUE
-5
TRUE
-3
TRUE
-3
TRUE
-3
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint16
Uint8
5
5
Int16
Int16
Uint16
Uint8
Int16
Int16
Uint16
Uint8
Int16
Int16
Int16
Int16
Int32
Int32
Uint16
Type
Uint8
Uint8
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
289