Rs-Ff Operand R - Danfoss VLT AutomationDrive FC 302 Programming Manual

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Parameter Descriptions
13-15 RS-FF Operand S
Option:
Function:
[85]
Digital input x46/13
[90]
ATEX ETR cur.
warning
[91]
ATEX ETR cur. alarm
[92]
ATEX ETR freq.
warning
[93]
ATEX ETR freq. alarm
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
[102] Relay 1
[103] Relay 2
[104] Relay 3
X47/VLT
113.
[105] Relay 4
X47/VLT
113.
[106] Relay 5
X47/VLT
113.
[107] Relay 6
X47/VLT
113.
[108] Relay 7
X34/VLT
[109] Relay 8
X34/VLT
[110] Relay 9
X34/VLT
NOTICE
[222] Homing Ok
This option is available only
with software version 48.20
and newer.
Homing is completed with the
selected homing function
(parameter 17-80 Homing Function).
NOTICE
[223] On Target
This option is available only
with software version 48.20
and newer.
Positioning is completed and the
on-target signal is sent when the
actual position is within
parameter 3-05 On Reference
Window for the duration of
parameter 3-09 On Target Time and
the actual speed does not exceed
parameter 3-05 On Reference
Window.
MG33MP02
Programming Guide
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Relay Card MCB 105.
®
Relay Card MCB 105.
®
Relay Card MCB 105.
Danfoss A/S © 10/2018 All rights reserved.
13-15 RS-FF Operand S
Option:
Function:
NOTICE
[224] Position Error
This option is available only
with software version 48.20
and newer.
The position error exceeds the
value in parameter 4-71 Maximum
Position Error for the time set in
parameter 4-72 Position Error
Timeout.
NOTICE
[225] Position Limit
This option is available only
with software version 48.20
and newer.
The position is outside the limits
set in parameter 3-06 Minimum
Position and
parameter 3-07 Maximum Position.
NOTICE
[226] Touch on Target
This option is available only
with software version 48.20
and newer.
Target position is reached in touch
probe position mode.
NOTICE
[227] Touch Activated
This option is available only
with software version 48.20
and newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.

3.13.4 13-16 RS-FF Operand R

13-16 RS-FF Operand R
Option:
Function:
[0]
False
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
3
3
175

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 301

Table of Contents