Parameter Descriptions

8-42 PCD Write Configuration

Range:
Function:
Size
[0 -
Select the parameters to be assigned to
related
9999 ]
the PCD's telegrams. The number of
*
available PCDs depends on the telegram
type. The values in the PCDs are then
written to the selected parameters as
data values.
8-43 PCD Read Configuration
Range:
Function:
Size
[0 -
Select the parameters to be assigned to
related
9999 ]
the PCDs of the telegrams. The number
*
of available PCDs depends on the
telegram type. PCDs contain the actual
data values of the selected parameters.

8-45 BTM Transaction Command

Option:
Function:
NOTICE
This parameter cannot be
adjusted while the motor is
running.
[0]
Off
*
[1]
Start Transaction
[2]
Commit transaction
[3]
Clear error
8-46 BTM Transaction Status
Option:
[0]
Off
*
[1]
Transaction Started
[2]
Transaction Comitting
[3]
Transaction Timeout
[4]
Err. Non-existing Par.
[5]
Err. Par. Out of Range
[6]
Transaction Failed
[7]
SO Config Check
[8]
SO Config Check Done
8-47 BTM Timeout
Range:
Function:
60 s
[1 - 360 s] Select the BTM timeout after a BTM
*
transaction has been started.
8-48 BTM Maximum Errors
Range:
Function:
21
[0 - 21 ] Selects the maximum allowed number of bulk
*
transfer mode errors before aborting. If it is set to
maximum, there is no abort.
MG33MP02
Programming Guide
8-49 BTM Error Log
Range:
0.255
*

3.9.5 8-5* Digital/Bus

Parameters for configuring the control word merging.
NOTICE
These parameters are active only when
parameter 8-01 Control Site is set to [0] Digital and control
word.

8-50 Coasting Select

Select the trigger for the coasting function.
Option:
[0]
Digital input A digital input triggers the coasting function.
[1]
Bus
[2]
Logic AND
[3]
Logic OR
*
8-51 Quick Stop Select
Function:
Select the trigger for the quick stop function.
Option:
[0]
[1]
[2]
[3]
*
8-52 DC Brake Select
Select control of the DC brake via the terminals (digital input)
and/or via the fieldbus.
Option:
[0] Digital input Activate a start command via a digital input.
[1] Bus
[2] Logic AND
Danfoss A/S © 10/2018 All rights reserved.
Function:
[0.000 -
List of parameters that failed during
9999.255 ]
bulk transfer mode. The value after the
decimal break is the fault code (255
stands for no error).
Function:
A serial communication port or the fieldbus
triggers the coasting function.
The fieldbus/serial communication port and a
digital input trigger the coasting function.
The fieldbus/serial communication port or a
digital input triggers the coasting function.
Digital input
Bus
Logic AND
Logic OR
Function:
NOTICE
When parameter 1-10 Motor Construction
is set to [1] PM non-salient SPM, only
selection [0] Digital input is available.
Activate a start command via the serial
communication port or fieldbus option.
Activate a start command via the fieldbus/serial
communication port and also via 1 of the
digital inputs.