Logging Source; Logging Interval; Trigger Event; Logging Mode - Danfoss VLT AutomationDrive FC 302 Programming Manual

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Parameter Descriptions

15-10 Logging Source

Option:
[1628] Angle Error
[1630] DC Link Voltage
[1632] Brake Energy /s
[1633] Brake Energy Average
[1634] Heatsink Temp.
[1635] Inverter Thermal
[1645] Motor Phase U Current
[1646] Motor Phase V Current
[1647] Motor Phase W Current
[1648] Speed Ref. After Ramp [RPM]
[1650] External Reference
[1651] Pulse Reference
[1652] Feedback[Unit]
[1657] Feedback [RPM]
[1660] Digital Input
[1662] Analog Input 53
[1664] Analog Input 54
[1665] Analog Output 42 [mA]
[1666] Digital Output [bin]
[1675] Analog In X30/11
[1676] Analog In X30/12
[1677] Analog Out X30/8 [mA]
[1687] Bus Readout Alarm/Warning
[1689] Configurable Alarm/Warning Word
[1690] Alarm Word
[1692] Warning Word
[1694] Ext. Status Word
[1695] Ext. Status Word 2
[1697] Alarm Word 3
[1698] Warning Word 3
[1843] Analog Out X49/7
[1844] Analog Out X49/9
[1845] Analog Out X49/11
[1860] Digital Input 2
[3110] Bypass Status Word
[3466] SPI Error Counter
[3470] MCO Alarm Word 1
[3471] MCO Alarm Word 2

15-11 Logging Interval

Array [4]
Range:
Size related
[ 0.000 - 0.000 ] Enter the interval in ms between
*
MG33MP02
Programming Guide
Function:
This option is only
available for software
version 48.XX
Function:
each sampling of the variables to
be logged.
Danfoss A/S © 10/2018 All rights reserved.

15-12 Trigger Event

Select the trigger event. When the trigger event occurs, a
window is applied to freeze the log. The log then retains a
specified percentage of samples before the occurrence of the
trigger event (parameter 15-14 Samples Before Trigger).
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current Limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5

15-13 Logging Mode

Option:
Function:
[0]
Log always
Select [0] Log always for continuous logging.
*
[1]
Log once
Select [1] Log once on trigger to start and stop
on trigger
logging conditionally using
parameter 15-12 Trigger Event and
parameter 15-14 Samples Before Trigger.
3
3
Function: