Parameter Descriptions
16-68 Freq. Input #33 [Hz]
Range:
0
[0 - 130000 ] View the actual value of the frequency
*
3
3
16-69 Pulse Output #27 [Hz]
Range:
0
[0 - 40000 ] View the actual value of pulses applied to
*
16-70 Pulse Output #29 [Hz]
Range:
0
[0 - 40000 ]
*

16-71 Relay Output [bin]

Range:
0
[0 - 511 ]
*
16-72 Counter A
Range:
0
[-2147483648
*
- 2147483647 ]
16-73 Counter B
Range:
0
[-2147483648
*
- 2147483647 ]
214
VLT
Function:
applied at terminal 33 as an impulse input.
Function:
terminal 27 in digital output mode.
Function:
NOTICE
This parameter is available for FC 302
only.
View the actual value of pulses at terminal 29
in digital output mode.
Function:
View the settings of all relays.
Illustration 3.69 Relay Settings
Function:
View the present value of counter A.
Counters are useful as comparator operands,
see parameter 13-10 Comparator Operand.
Reset or change the value either via digital
inputs (parameter group 5-1* Digital Inputs)
or by using an SLC action
(parameter 13-52 SL Controller Action).
Function:
View the present value of counter B.
Counters are useful as comparator operands
(parameter 13-10 Comparator Operand).
Reset or change the value either via digital
inputs (parameter group 5-1* Digital Inputs)
or by using an SLC action
(parameter 13-52 SL Controller Action).
Danfoss A/S © 10/2018 All rights reserved.
®
AutomationDrive FC 301/302

16-74 Prec. Stop Counter

Range:
0
[0 - 2147483647 ] Returns the actual counter value of
*
16-75 Analog In X30/11
Range:
0
[-20 - 20 ] View the actual value at input X30/11 of VLT
*
16-76 Analog In X30/12
Range:
0
[-20 - 20 ] View the actual value at input X30/12 of VLT
*
16-77 Analog Out X30/8 [mA]
Range:
0
[0 - 30 ]
*
16-78 Analog Out X45/1 [mA]
Range:
0
[0 - 30 ] Shows the actual output value at terminal X45/1.
*
16-79 Analog Out X45/3 [mA]
Range:
0
[0 - 30 ] Shows the actual output value at terminal X45/3.
*
3.16.6 16-8* Fieldbus & FC Port
Parameters for reporting the bus references and control
words.

16-80 Fieldbus CTW 1

Range:
0
[0 -
*
65535 ]
16-81 Fieldbus Sync. REF
Range:
0
[-2147483648 -
*
2147483647 ]
Function:
precise counter (parameter 1-84 Precise
Stop Counter Value).
Function:
General Purpose I/O MCB 101.
Function:
General Purpose I/O MCB 101.
Function:
View the actual value at input X30/8 in mA.
Function:
The value shown reflects the selection in
parameter 6-70 Terminal X45/1 Output.
Function:
The value shown reflects the selection in
parameter 6-80 Terminal X45/3 Output.
Function:
View the two-byte Control word (CTW) received
from the Bus-Master. Interpretation of the CTW
depends on the fieldbus option installed and the
CTW profile selected in parameter 8-10 Control
Word Profile.
For more information, refer to the relevant
fieldbus manual.
Function:
Only active for Ethernet based
fieldbus options. Read out of master
position for synchronizing via
fieldbus.
®
®
MG33MP02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 301

Table of Contents